    无溶剂环氧防静电地坪涂料配方:将环氧树脂、颜料、填料、活性与非活性稀释剂、助剂等混合搅拌均匀,在三辊磨上研磨至一定细度,加入导电粉,均匀分散,制得环氧防静电地坪涂料主剂;涂装时将主剂和等当量的固化剂混合均匀,即可以镘涂方式进行自流平施工。无溶剂防静电自流平自流平环氧地坪花开棋牌不受时间、温度、湿度等影响;漆膜表面平滑、美观,达镜面效果;耐磨、耐压、耐冲击;耐化学腐蚀,特别是耐碱性能好;生产施工过程简单、方便,基本无VOC排放,有利于环保。

    Solvent-free epoxy anti-static floor coating formulation: mix epoxy resin, pigments, fillers, active and inactive diluents, additives and other mixtures evenly, grind them to a certain fineness on three-roll mill, add conductive powder, evenly disperse, to prepare the main agent of epoxy anti-static floor coating; mix the main agent and the equivalent curing agent in painting. Uniform, self-leveling construction can be carried out by upsetting. Solvent-free anti-static self-leveling and self-leveling epoxy floor is not affected by time, temperature and humidity; the surface of the paint film is smooth and beautiful, reaching mirror effect; wear resistance, pressure resistance and impact resistance; chemical corrosion resistance, especially alkali resistance; production and construction process is simple and convenient, basically no VOC emissions, conducive to environmental protection.

    防静电,环氧自流平地坪,涂料配方及施工工艺

    Anti-static, epoxy self-leveling floor, paint formulation and construction technology

    环氧防静电地坪涂料及涂装系统优良的性能满足了现代科技和生产发展对环氧地坪高度清洁和防静电的要求,具有显著的经济效益和社会效益,应用现状和前景十分广阔。

    The excellent performance of epoxy anti-static floor coating and coating system meets the requirements of modern science and technology and production development for high cleanliness and anti-static floor. It has remarkable economic and social benefits, and its application status and prospects are very broad.

    1、环氧防静电施工准备

    1. Construction preparation of epoxy anti-static floor

    工具:水泥打磨机、吸尘器、搅拌机、计量器具、刮刀等。材料:防静电环氧底漆(主剂和固化剂)、无溶剂防静电环氧自流平面漆(主剂和固化剂)、导电铜箔、石英砂、石英粉等。

    Tools: cement grinder, vacuum cleaner, mixer, measuring instrument, scraper, etc. Material: Antistatic Epoxy Primer (main agent and curing agent), solvent-free Antistatic Epoxy self-flow flat paint (main agent and curing agent), conductive copper foil, quartz sand, quartz powder, etc.

    环氧防静电地坪施工准备

    Construction preparation of epoxy anti-static floor

    花开棋牌2、环氧防静电地坪基层处理:

    2。 Epoxy anti-static floor base treatment:

    施工时须清除混凝土地坪基层的水泥凸起物及空鼓,对开裂及有缺陷的孔洞进行修补,清除油污和潮湿部分,然后进行打磨处理,获得适当的表面粗糙度,必要时需喷砂处理。施工现场要求:空气相对湿度小于85%,气温不低于5℃。

    During construction, it is necessary to remove the cement bumps and hollow drums of the concrete floor base, repair the cracked and defective holes, remove the oil and wet parts, and then grind them to obtain proper surface roughness, and sand blasting treatment is necessary. Construction site requirements: the relative humidity of air is less than 85%, and the temperature is not less than 5 C.

    环氧防静电地坪基层处理

    Treatment of Epoxy Antistatic Floor Base

    3、环氧防静电地坪施工工艺

    3。 Construction Technology of Epoxy Antistatic Floor

    (1)防静电底涂。

    花开棋牌(1) Antistatic primer.

    将防静电底漆搅拌均匀后,用刮刀满刮地坪。

    After stirring the anti-static primer evenly, scrape the floor with a scraper.

    (2)贴导电铜箔。

    (2) Paste conductive copper foil。

    待底漆干燥后,测量地坪的电阻率(要求l04Ω·m以下),按3m×3m的间隔贴导电铜箔,建立静电耗散泄漏层,并按每500m2接一个接地装置,组成完整的静电泄漏体系。

    After the primer is dried, the resistivity of the floor (requiring less than l04_. m) is measured, conductive copper foil is pasted at intervals of 3M * 3m, and the electrostatic dissipation leakage layer is established. A grounding device is connected to each 500m 2 to form a complete electrostatic leakage system.

    花开棋牌环氧防静电地坪施工工艺

    Construction Technology of Epoxy Antistatic Floor

    (3)刮环氧防静电砂浆中层漆。

    (3) Scraping epoxy anti-static mortar mid-coat paint.

    用防静电底漆和石英砂按一定的配比搅拌均匀调成环氧防静电砂浆,用刮刀满刮地坪1~3遍(具体遍数视工程厚度要求而定),每遍环氧砂浆刮涂厚度控制在1mm。

    The epoxy anti-static mortar is evenly mixed with anti-static primer and quartz sand according to a certain mixing ratio. The floor is scraped with a scraper for 1-3 times (depending on the thickness of the project), and the scraping thickness of the epoxy mortar is controlled at 1 mm per time.

    (4)刮第一遍腻子。

    (4) Scrape putty for the first time.

    环氧防静电砂浆中层漆干燥后,测量地坪的电阻率(要求104Ω·m以下)。用环氧防静电底漆和石英粉按配比搅拌均匀调成环氧防静电腻子,用刮刀满刮一遍,然后对部分有缺陷孔洞进行点补。

    After the epoxy anti-static mortar mid-coat is dried, the resistivity of the floor is measured (requiring less than 104_. m). Epoxy anti-static primer and quartz powder are stirred in proportion to form epoxy anti-static putty. Scraper is used to scrape all over the putty, and then some defective holes are repaired.

    (5)刮第二遍腻子。

    (5) Scrape putty twice。

    第一遍腻子干燥后,用无溶剂环氧防静电地坪涂料主剂、固化剂和石英粉按配比搅拌均匀调成环氧面漆腻子,用刮刀满刮一遍。

    After the first time of putty drying, the main agent, curing agent and quartz powder of solvent-free epoxy anti-static floor paint are mixed evenly into epoxy topcoat putty, which is scraped once with a scraper.

    (6)打磨。

    (6) Grinding.

    第二遍腻子干燥后点补孔洞,然后用细砂皮纸整体打磨、吸尘。

    The second time the putty is dried, the hole is filled, then the whole putty is polished and cleaned with fine sandpaper.

    (7)镘涂防静电环氧自流平面漆。

    (7) Anti-static epoxy self-flow surface paint is applied by dysprosium.

    测量地坪的电阻率(要求105Ω·m以下),将无溶剂防静电环氧自流平主剂和固化剂按配比混合搅拌均匀,用镘刀进行自流平施工,同时用消泡滚筒进行消泡,确保表面颜色均匀。

    Measure the resistivity of the floor (requiring less than 105_. m). Mix the solvent-free anti-static epoxy self-leveling agent and curing agent in proportion, mix and mix evenly. Self-leveling construction is carried out with a trowel, and defoaming drum is used to defoam the surface to ensure uniform color. 